Assessing the representative elementary volume of rock types by X-ray computed tomography (CT) – a simple approach to demonstrate the heterogeneity of the Boda Claystone Formation in Hungary
PDF

Keywords

Hounsfield Unit (HU)
Autoregressive Integrated Moving Averages (ARIMA)
Statistical Process Control (SPC) technique

How to Cite

Abutaha, S. M., Geiger, J., Gulyás, S., & Fedor, F. (2021). Assessing the representative elementary volume of rock types by X-ray computed tomography (CT) – a simple approach to demonstrate the heterogeneity of the Boda Claystone Formation in Hungary. Geologos, 27(3), 157–172. https://doi.org/10.2478/logos-2021-0018

Abstract

X-ray computed tomography (CT) can reveal internal, three-dimensional details of objects in a non-destructive way and provide high-resolution, quantitative data in the form of CT numbers. The sensitivity of the CT number to changes in material density means that it may be used to identify lithology changes within cores of sedimentary rocks. The present pilot study confirms the use of Representative Elementary Volume (REV) to quantify inhomogeneity of CT densities of rock constituents of the Boda Claystone Formation. Thirty-two layers, 2 m core length, of this formation were studied. Based on the dominant rock-forming constituent, two rock types could be defined, i.e., clayey siltstone (20 layers) and fine siltstone (12 layers). Eleven of these layers (clayey siltstone and fine siltstone) showed sedimentary features such as, convolute laminations, desiccation cracks, cross-laminations and cracks. The application of the Autoregressive Integrated Moving Averages, Statistical Process Control (ARIMA SPC) method to define Representative Elementary Volume (REV) of CT densities (Hounsfield unit values) affirmed the following results: i) the highest REV values corresponded to the presence of sedimentary structures or high ratios of siltstone constituents (> 60%). ii) the REV average of the clayey siltstone was (5.86 cm3) and (6.54 cm3) of the fine siltstone. iii) normalised REV percentages of the clayey siltstone and fine siltstone, on the scale of the core volume studied were 19.88% and 22.84%; respectively. iv) whenever the corresponding layer did not reveal any sedimentary structure, the normalised REV values would be below 10%. The internal void space in layers with sedimentary features might explain the marked textural heterogeneity and elevated REV values. The drying process of the core sample might also have played a significant role in increasing erroneous pore proportions by volume reducation of clay minerals, particularly within sedimentary structures, where authigenic clay and carbonate cement were presumed to be dominant.

https://doi.org/10.2478/logos-2021-0018
PDF

References

Abutaha, S.M., Geiger, J., Gulyás, S. & Fedor, F., 2021. Evaluation of 3D small-scale lithological heterogeneities and pore distribution of the Boda Claystone Formation using X-ray computed tomography images (CT). Geologia Croatica 74/3. doi: 10.4154/gc.2021.17

Akin, S. & Kovscek, A.R., 2003. Computed tomography in petroleum engineering research. [In:] Mees, F., Swennen, R., Van Geet, M. & Jacobs, P. (Eds): Application of X-ray computed tomography in the geosciences. Special Publication, Geological Society of London, 215, 23–38.

Al-Raoush, R. & Willson, C.S., 2005. Extraction of physically-representative pore network from unconsolidated porous media systems using synchrotron microtomography, Journal of Hydrology 23, 274–299.

Árkai, P., Balogh, K., Demény, A., Fórizs, I., Nagy, G. & Máthé, Z., 2000. Composition, diagenetic and post-diagenetic alterations of a possible radioactive waste repository site: the Boda Albitic Claystone Formation, southern Hungary. Acta Geologica Hungarica 43, 351-378.

Balázs, G.Y.L., Lublóy, É. & Földes, T., 2018. Evaluation of concrete elements with X-Ray computed tomography. Journal of Materials in Civil Engineering 30, 1-9.

Barabás, A. & Barabás-Stuhl, Á., 1998. Stratigraphy of the Permian formations in the Mecsek Mountains and its surroundings. [In:] Stratigraphy of geological formations of Hungary. Geological and Geophysical Institute of Hungary, 187-215 (in Hungarian).

Baveye, P., Rogasik, H., Wendroth, O., Onasch, I. & Crawford, J.W., 2002. Effects of sampling volume on the measurement of soil physical properties: simulation with X-ray tomography data. Measurement Science and Technology, 13, 775–784.

Bear, J., 1972. Dynamics of fluids in porous media. Dover Publications Inc., New York, 764 pp.

Bear, J. & Bachmat, Y., 1990. Introduction to Modeling of Transport Phenomena in Porous Media. Kluwer Academic Press, Dordrecht, 575 pp.

Blum, P., Mackay, R., Riley, M. & Knight, J., 2007. Performance assessment of a nuclear waste repository: up-scaling coupled hydro-mechanical properties for far-field transport analysis. International Journal of Rock Mechanics and Mining Sciences 42, 781–792.

Box, G.E.P., Jenkins, G.M. & Reinsel, G.C., 1994. Time series analysis: Forecasting and control. 3rd Edition. Prentice Hall, Englewood Cliff, New Jersey, 619 pp.

Brown, G.O., Hsieh, H.T. & Lucero, D.A., 2000. Evaluation of laboratory dolomite core sample size using representative elementary volume concepts, Water Resources Research 36, 1199–1208.

Bush, D.C. & Jenkins, R.E., 1975. Proper Hydration of Clays for Rock Property Determinations. Journal of Petroleum Technology 22, 800-804.

Chang, C.S. & Gao, J., 1995. Second-gradient constitutive theory for granular material with random packing structure, International Journal of Solids and Structures, 32, 2279–2293.

Clausnitzer, V. & Hopmans, J.W., 1999. Determination of phase-volume fractions from tomographic measurements in two-phase systems, Advances in Water Resources 22, 577–584.

Cnudde, V., Masschaele, B., Dierick, M., Vlassenbroeck, J., Van Hoorebeke, L. & Jacobs, P., 2006. Recent progress in X-ray CT as a geosciences tool. Applied Geo-chemistry 21, 826–832.

Cnudde, V., Dewanckele, J., De Boever, W., Brabant, L., De Kock, T., 2012. 3D characterization of grain size distributions in sandstone by means of X-ray computed tomography. In: Sylvester, P. (Ed.), Quantitative Mineralogy and Microanalysis of Sediments and Sedimentary Rocks. Mineralogical Association of Canada (MAC), 42, 99–113.

Coles, M.E., Hazlett, R.D., Spanne, P., Soll, W.E., Muegge, E.L. & Jones, K.W., 1998. Pore level imaging of fluid transport using synchrotron X-ray microtomography. Journal of Petroleum Science and Engineering 19, 55–63.

Coles, M.E., Muegge, E.L. & Sprunt, E.S., 1991. Applications of CAT scanning for oil and gas-production research. IEEE Transactions on Nuclear Science 38, 510–515.

Cormack, A.M. & Hounsfield, G.N., 1989. Physiology or medicine 1979: Press release. Accessed April 21, 2018. https://www.nobelprize.org/nobel_prizes/medicine/laureates/1979/press.html.

Duchesne, M.J., Moore, F., Long, B.F. & Labrie, J., 2009. A rapid method for converting medical Computed Tomography scanner topogram attenuation scale to Hounsfield Unit scale and to obtain relative density values. Engineering Geology 103, 100–105.

Feyel, F. & Chaboche, J.-L., 2000. FE2 multiscale approach for modelling the elasto-viscoplastic behavior of long fiber SiC/Ti composite materials. Computer Methods in Applied Mechanics and Engineering 183, 309–330.

Földes, T., 2011. Integrated processing based on CT measurement. Journal of Geometry and Physics 1, 23–41.

Földes, T., Kiss, B., Árgyelán, G., Bogner, P., Repa, I. & Hips, K., 2004. Application of medical computer tomography measurements in 3D reservoir characterization. Acta Geologica Hungarica, 47, 63–73.

Gang, W., Shen, J., Liu, Sh., Jiang, Ch., Qin, X., 2019. Three-dimensional modeling and analysis of macro-pore structure of coal using combined X-ray CT imaging and fractal theory. International Journal of Rock Mechanics and Mining Sciences,123,104082. https://doi.org/10.1016/j.ijrmms.2019.104082.

Garvey, C.J. & Hanlon, R., 2002. Computed tomography in clinical practice. British Medical Journal 324, 1077–1080.

Geiger, J., 2018. Statistical process control in the evaluation of geostatistical simulations. Central European Geology, 6/1, 50-72.

Gordon, N.J., Salmond, D.J. & Smith, A.F.M., 1993. Novel approach to nonlinear/non-Gaussian Bayesian state estimation, IEE Proceedings F (Radar and Signal Processing) 40, 107-113.

Haas, J.& Péró, C.S., 2004. Mesozoic evolution of the Tisza Mega-unit. International Journal of Earth Sciences 93, 297–313.

Heismann, B.J., Leppert, J. & Stierstorfer, K., 2003. Density and atomic number measurements with spectral x-ray attenuation method. Journal of Applied Physics 94, 2073-2079.

Herman, G.T., 2009. Fundamentals of computerized tomography: Image reconstruction from projection. 2nd ed., Springer, 300 pp.

Hounsfield, G.N., 1973. Computerized transverse axial scanning (tomography). 1. Description of system. British Journal of Radiology 46, 1016-1022.

Hove, A.O., Ringen, J.K. & Read, P.A. 1987.Visualization of laboratory corefloods with the aid of computerized tomography of X-rays. Society of Petroleum Engineers Reservoir Engineering 2, 148-154.

Keelan, D.K., 1982. Core analysis for aid in reservoir description. Journal of Petroleum Technology 34, 2483-2489.

Ketcham, R.A. & Carlson, W.D., 2001. Acquisition, optimization and interpretation of X-ray computed tomo-graphic imagery: applications to geosciences. Computational Geosciences 27, 381–400.

Konrád, G.Y., Sebe, K., Halász, A. & Babinszki, E., 2010. Sedimentology of a Permian playa lake: The Boda Claystone Formation, Hungary. Geologos 16, 27–41.

Kouznetsova, V., Brekelmans, W.A.M. & Baaijens, F.P.T., 2001. An approach to micro–macro modelling of heterogeneous materials. Computational Mechanics 27, 37–48.

Kouznetsova, V., Geers, M.G.D. & Brekelmans, W.A.M., 2002. Multi-scale constitutive modelling of heterogeneous materials with a gradient-enhanced computational scheme. International Journal for Numerical Methods in Engineering 54, 1235–1260.

Long, J., Remer, J., Wilson, C. & Witherspoon, P., 1982. Porous media equivalents for networks of discontinuous fractures. Water Resources Research 18, 645–658.

Louis, L., Wong, T.F. & Baud, P., 2007. Imaging strain localization by X-ray radiography and digital image correlation: deformation bands in Rothbach sandstone. Journal of Structural Geology 29, 129–140.

Máthé, Z., 1998. Summary report of the site characterization program of the Boda Siltstone Formation. Mecsek Ore Environment Company, Pécs, 4.

Máthé, Z. & Varga, A., 2012. “Ízesíto” a permi Bodai Agyagko Formáció oskörnyezeti rekonstrukciójához: kosó utáni pszeudomorfózák a BAT-4 fúrás agyagkomintáiban. [“Seasoning” to the palaeoenvironmental reconstruction of the Permian Boda Claystone Formation: pseudomorphs after halite in the claystone samples of the deep drillings BAT-4]. Földtani Közlöny 142, 201-204 (in Hungarian with English summary).

Montgomery, D.C., 1997. Introduction to Statistical Quality Control. John Wiley and Sons, New York, 759 pp.

Muhlhaus, H.B. & Oka, F., 1996. Dispersion and wave propagation in discrete and continuous models for granular materials. International Journal of Solids and Structures 33, 271–283.

Németh, T. & Máthé, Z., 2016. Clay mineralogy of the Boda Claystone Formation (Mecsek Mts., SW Hungary). Open Geoscience 8, 259–274.

Oakland, J.S., 2003. Statistical process control. Butter-worth-Heineman, Oxford, 460 pp.

Peerlings, R.H.J. & Fleck, N.A., 2001. Numerical analysis of strain gradient effects in periodic media. Journal De Physique IV, 11, 153–160.

Polhemus, N.W., 2005. How to: Construct a control chart for autocorrelated data. StatPoint Technologies, Herndon, 16 pp.

Russo, D. & Jury, W.A., 1987. A theoretical study of the estimation of the correlation scale in spatially varied fields, 2. Nonstationary fields. Water Resources Research 23, 1269–1279.

Russo, S.L., Camargo, M.E. & Fabris, J.P., 2012. Applications of control charts ARIMA for autocorrelated data. [In:] Nezhad, M.S.F. (Ed.): Practical Concepts of Quality Control. InTech, Rijeka, 31–53.

Shapiro, A.M. & Andersson, J., 1983. Steady state fluid response in fractured rock: a boundary element solution for a coupled, discrete fracture continuum model. Water Resources Research 19, 959–969.

Shewhart, W.A., 1931. Economic control of quality of the manufactured product. Van Nostrand, New York, 501 pp.

Soeder, D.J., 1986. Laboratory drying procedures and the permeability of tight sandstone core. SPE Formation Evaluation 1, 16-22.

Sutton, S.R., Bertsch, P.M., Newville, M., Rivers, M., Lanzirotti, A. & Eng, P., 2002. Microfluorescence and microtomography analyses of heterogeneous earth and environmental materials. Reviews in Mineralogy and Geochemistry 49, 429–483.

Taud, H., Martinez-Angeles, T.R., Parrot, J.F. & Hernandez-Escobedo, L., 2005. Porosity estimation method by X-ray computed tomography. Journal of Petroleum Science and Engineering 47, 209 – 217.

Van Geet, M., Swennen, R. & Wevers, M., 2000. Quantitative analysis of reservoir rocks by microfocus X-ray computerised tomography. Sedimentary Geology 132, 25–36.

Van Kaick, G. & Delorme, S., 2005. Computed tomography in various fields outside medicine. European Radiology 15, D74–D81.

Varga, A.R., Szakmány, G.Y., Raucsik, B. & Máthé, Z., 2005. Chemical composition, provenance and early diagenetic processes of playa lake deposits from the Boda Siltstone Formation (Upper Permian), SW Hungary. Acta Geologica Hungarica 48, 49–68.

Vinegar, H.J., Wellington, S.L., 1987. Tomographic imaging of three-phase flow experiments. Review of Scientific Instruments. 58 /1, 96–107.

Webster, R., 2000. Is soil variation random? Geoderma 97, 149–163.

Wesolowski, J.R. & Lev, H.M., 2005. CT: History, technology, and clinical aspects. Seminars in Ultrasound, CT and MRI 26, 376–379.

Withjack, E.M., 1988. Computed tomography for rock property determination and fluid flow visualization. SPE Formation Evaluation 3, 696-704.